7 calibration mode, English, Flow rate controller 8039 – Burkert Type S039 User Manual

Page 22: Programming . calibration mode, Min, m

Advertising
background image

ENGLISH

ENGLISH

flow rate controller 8039

** To use the «Teach-In» feature, connect the 8039 controller to a valve which makes it possible to fill a tank with a capacity of
x litres (200 litres for instance).
When the display shows «YES TEAC», press the «ENTER» key and open the valve: The «TEAC» message flashes.

When the tank is full (200 litres), press «ENTER» again. By means of keys

0......9

and

ENTER

enter the volume of fluid which

circulated through the circuit (200 litres): the controller calculates the K factor and displays it.

OHI>

OLO

0......9

ENTER

1

ENTER

0......9

ENTER

0......9

2

ENTER

ENTER

ENTER

ENTER

ENTER

0......9

0......9

ENTER

ENTER

0......9

0......9

0......9

ENTER

ENTER

ENTER

0......9

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

0......9

...

ENTER

0......9

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

0......9

0......9

*

*

*

*

*

*

to enter

the K-factor (refer

to the fitting manual) or have
it calculated through the
Teach-in feature.
K is the multiplication coeffi-
cient between the rotational
frequency of the S039 pad-
dle-wheel and the flow rate to
be measured.



proGramminG

. calibration mode

to choose

the flow rate unit

(l/s, l/min, l/h, m

3

/min, m

3

/h,

Ga/s, Ga/min, Ga/h).

to go back

to the previous

function.
to go to

the next function.

if you change the flow rate unit,
change the switching threshold
values, too.

UNIT

L/S

GA/H

KFAC

NO

TEAC

YES

TEAC

TEAC

0.534

KFAC

200.0

L/S

0.534

KFAC

**

* To move the decimal point, press simultaneously keys

0......9

and