Burkert Type 8112 User Manual

Page 31

Advertising
background image

1

2

-50 °C

(-58 °F)

0 °C

(32 °F)

50 °C

(122 °F)

100 °C

(212 °F)

150 °C

(302 °F)

200 °C

(392 °F)

250 °C

(482 °F)

20

(290)

-1 (-14,5)

40

(580)

64

(928)

Fig. 31: Process temperature - Process pressure with switch position 0.5 g/cm³ (sensitivity switch)

1

Process pressure in bar (psig)

2

Process temperature in °C (°F)

Viscosity - dynamic

0.1 … 10,000 mPa s (requirement: with density 1)

Flow velocity

max. 6 m/s (with a viscosity of 1 mPa s)

Density

0.7 … 2.5 g/cm³ (0.025 … 0.09 lbs/in³); 0.5 … 2.5 g/
cm³ (0.018 … 0.09 lbs/in³) by switching over

Electromechanical data

Cable entry/plug (dependent on the version)

-

Single chamber housing

l

1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; attached 1 x cable
entry M20 x 1.5

or:

l

1 x cable entry ½ NPT, 1 x blind stopper ½ NPT,
1 x cable entry ½ NPT

or:

l

1 x plug M12 x 1; 1 x blind stopper M20 x 1.5

Screw terminals

for wire cross-section up to 1.5 mm² (AWG 16)

Adjustment elements

Mode switch

-

A

Max. detection or overflow/overfill protection

-

B

Min. detection or dry run protection

Density changeover switch

-

0.5

0.5 … 2.5 g/cm³ (0.018 … 0.9 oz/in³)

-

0.7

0.7 … 2.5 g/cm³ (0.025 … 0.9 oz/in³)

Voltage supply

Operating voltage

LEVEL SWITCH