Hydrotech EBP75TFC-3SF Replacing the Auto Shutoff With a Solenoid Valve on Economy Reverse Osmosis C_W Booster Pump User Manual

Replacement instructions

Advertising
background image

Replacing the Auto Shutoff With a Solenoid Valve on Economy

Reverse Osmosis C/W Booster Pump (Model # EBP75TFC-3SF)

The kit (Part #92374) consists of the following

a)

Solenoid Valve 24V (Qty 1)

b)

Blue Wire Nuts (Qty 2)

c)

Blue ¼” Tubing (9” length)

d)

Red ¼” Tubing (14” length)

e)

Black ¼” Tubing (19” Length)

f)

Pull Ties (2)

g)

Elbow ¼” NPT X ¼” Quick Connect

h)

Adapter ¼” NPT X ¼” Quick Connect

i)

Screw for the mounting the solenoid to the RO Bracket

Please verify that you have received all the components in the kit as described above

Tools Required:

• 11/16” Wrench

• Knife or Wire Stripper

• Phillips Screwdriver

Replacement Instructions

1. Disconnect the booster pump power supply.

2. Unscrew the white compression nut from the membrane housing using 11/16” wrench and disconnect the white tubing.

3. Remove the RO membrane housing from the clips and hang it to the side of the RO Module

#54920 1/11

RO Membrane

Housing

White

Compression

Nut

White Tubing

Disconnected

Advertising