Hydrotech EBP75TFC-3SF Replacing the Auto Shutoff With a Solenoid Valve on Economy Reverse Osmosis C_W Booster Pump User Manual
Replacement instructions
Replacing the Auto Shutoff With a Solenoid Valve on Economy
Reverse Osmosis C/W Booster Pump (Model # EBP75TFC-3SF)
The kit (Part #92374) consists of the following
a)
Solenoid Valve 24V (Qty 1)
b)
Blue Wire Nuts (Qty 2)
c)
Blue ¼” Tubing (9” length)
d)
Red ¼” Tubing (14” length)
e)
Black ¼” Tubing (19” Length)
f)
Pull Ties (2)
g)
Elbow ¼” NPT X ¼” Quick Connect
h)
Adapter ¼” NPT X ¼” Quick Connect
i)
Screw for the mounting the solenoid to the RO Bracket
Please verify that you have received all the components in the kit as described above
Tools Required:
• 11/16” Wrench
• Knife or Wire Stripper
• Phillips Screwdriver
Replacement Instructions
1. Disconnect the booster pump power supply.
2. Unscrew the white compression nut from the membrane housing using 11/16” wrench and disconnect the white tubing.
3. Remove the RO membrane housing from the clips and hang it to the side of the RO Module
#54920 1/11
RO Membrane
Housing
White
Compression
Nut
White Tubing
Disconnected