11. Connect one end of 9” blue tubing to the tee as shown below. Connect the other end of the blue tubing to the inlet of
the solenoid valve.
12. Connect the 19” black tubing to the inlet of the booster pump and connect the other end to the outlet of the solenoid as
shown below.
13. Disconnect the white tubing from the elbow of the middle sump.
Tee
Blue Tubing
Blue Tubing
Black
Tubing
Black
Tubing
Disconnect white
tubing from
middle sump