14. Connect the 14” red tubing to the elbow of the middle sump. Connect the other end of the red tubing to the inlet of the

booster pump.

15. Take the white tubing collected from step 4. Connect the tubing (the end without the nut) to the high pressure switch.

Install the RO Membrane housing back to it clips and re-connect the other end of the white tubing to the membrane

housing.

16. Snip the cable ties holding the wires on to the bracket.

Wiring - Please refer to the wiring diagram at the last page. Identify the components as shown below

Solenoid Valve

Transformer

High Pressure Switch

Low Pressure Switch

Booster Pump

Red Tubing

Red Tubing

White Tubing