7. Remove the white tubing connection to the outlet of the booster pump.

8. Install the elbow (1/4” NPT X ¼” Quick Connect) supplied to the solenoid valve at the port where the arrow is pointing

towards. Install the adapter (1/4” NPT X ¼” Quick Connect) to the other side of the solenoid valve. Apply Teflon tape on

the threads of the fittings. Note the black arrow on the solenoid valve.

9. Attach solenoid valve to the bracket with the screw provided. Please refer to the pictures below.

10. Disconnect the white tubing from the tee as shown. Also disconnect the other end of this white tubing from the inlet of

the booster pump. Discard this white tubing.

Elbow

Fitting

Adapter

Fitting

Solenoid Valve

attached to the

Bracket

Disconnect white

tubing from the tee.

Disconnect white

tubing from

booster pump

inlet.

Disconnect tube

from Booster

Pump outlet

Attach the

solenoid

with screw

provided.