Hydrotech EBP75TFC-3SF Replacing the Auto Shutoff With a Solenoid Valve on Economy Reverse Osmosis C_W Booster Pump User Manual
Page 3
7. Remove the white tubing connection to the outlet of the booster pump.
8. Install the elbow (1/4” NPT X ¼” Quick Connect) supplied to the solenoid valve at the port where the arrow is pointing
towards. Install the adapter (1/4” NPT X ¼” Quick Connect) to the other side of the solenoid valve. Apply Teflon tape on
the threads of the fittings. Note the black arrow on the solenoid valve.
9. Attach solenoid valve to the bracket with the screw provided. Please refer to the pictures below.
10. Disconnect the white tubing from the tee as shown. Also disconnect the other end of this white tubing from the inlet of
the booster pump. Discard this white tubing.
Elbow
Fitting
Adapter
Fitting
Solenoid Valve
attached to the
Bracket
Disconnect white
tubing from the tee.
Disconnect white
tubing from
booster pump
inlet.
Disconnect tube
from Booster
Pump outlet
Attach the
solenoid
with screw
provided.