1.2 F

EATURES

Ultra ISC load cell features are:

 Factory Calibration promotes interchangeability

 Tension controller observation of individual load cell signals provides increased opportunity for

advanced diagnostics and calibration.

 Self contained precision excitation circuit eliminates the need for the expense and complication of

remote sense

 24V supply has reverse polarity protection

 Analog output buffer designed to accommodate capacitive cable loads.

 Floating strain-gage and output stage allows “stacking” ISC outputs for simple summing.

 Sealed enclosure and M12 connector provide environmental protection

 Industry standard M12 allows use of readily available molded cordsets

1.3 H

OW IS THE

U

LTRA

ISC

U

SED

The Ultra ISC load cell has been developed for those customers who desire to send the amplified transducer
signal directly into their Controller, PLC, PAC, Drive, or Local I/O.

The Ultra ISC load cell is shipped preset from CMC with 0 volts representing no load, and 10 volts
representing the 100% full rating of the transducer. (Example: A 100 lb Ultra ISC transducer with no load
outputs 0 volts. With a 100 lb. load the output is 10 VDC when loaded in one direction and -10VDC when
loaded in the opposite direction.)

1.4 CE

EMC

R

ESPONSIBILITY

The Integrated Signal Conditioning (ISC) Amplifier Ultra Series ISC module embedded in the load cell can
be considered a component performing a direct function and therefore is subject to the provisions of the
EMC Directive.

To assist manufacturers, suppliers, and installers of relevant apparatus, this amplifier module is compliant
to EN61326:1997 when installed according to these instructions. Manufacturers, suppliers, and installers
of relevant apparatus may use this compliance as a contributing basis for their own justification of overall
compliance with the EMC Directive.

Before installing the Ultra Series ISC Amplifier you must clearly understand who is legally responsible for
conformance with the EMC Directive. Misappropriation of the CE mark is a criminal offense.