8 operating conditions, 9 emc technical ratings, 10 emission specifications – Cleveland Motion Controls ULTRA ISC CANTILEVER TRANSDUCER CLTSCM REV AA User Manual

Page 12: Perating, Onditions, Echnical, Atings, Mission specifications, 9 emc, 10 e

Advertising
background image

U

LTRA

S

ERIES

ISC

C

ANTILEVER

T

RANSDUCER

T

ECHNICAL

M

ANUAL

MAN-70445-0

R

EV

AA

1.8 O

PERATING

C

ONDITIONS

Condition

Isolated Signal Conditioning Amplifier

Installation category

Category III

Pollution Pollution

Degree

2

Input supply

Earth (Ground) referenced

Protection Enclosure

mounted

1.9 EMC

T

ECHNICAL

R

ATINGS

Port

Phenomenon

Test Standard

Level

Test Standard

Enclosure

ESD

EN 61000-4-2:

8KV AD, 1KV CD

EN 61326:1997

Enclosure

RF Field

EN 61000-4-3

10V/m,1 Khz AM

EN 61326:1997

Transducer Leads

Fast Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

Output Leads

Fast Transient
Burst

EN 61000-4-4

1kV

EN 61326:1997

Transducer Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

Output Leads

Conducted
Immunity

EN 61000-4-6

3V/m

EN 61326:1997

1.10 E

MISSION SPECIFICATIONS

Port

Phenomenon

Test Standard

Level

Generic Standard

Enclosure Radiated

EN

61326:

1997

Class A

EN 61326:1997

The levels of performance indicated are achieved when the Isolated Signal Conditioning Amplifier is
installed by using the instructions and specifications outlined in this document.

4