Item:

Specification:

Transducer Weight

1T ALUM

1T STEEL

2T STEEL

1.9 lbs.
0.86 kg.

2.7 lb.
1.23 kg

3.7 lb.
1.68 kg

Weight + Mounting Kit

1T ALUM

1T STEEL

2T STEEL

Flange

2.9 lbs.
1.32 kg.

3.7 lbs.
1.68 kg

5.3 lbs.

2.41 kg

Bearing

2.3 lbs.
1.05 kg.

3.1 lbs.
1.41 kg.

4.2 lbs.
1.91 kg.

Pillow Block

4.8 lbs
2.18 kg.

5.6 lbs.
2.54 kg.

7.9 lbs.
3.59 kg.

Material

Strain Sensing beam - heat treated 4140 alloy steel

or 2024 T81 Aluminum

Body - 1117 Low Carbon steel

Finish Material

Corrosion resistant Zinc plated with clear Chromate

Gage Type

Semi-conductor strain gage, high gage factor (100 nominal)

Connector Type

M12 Quick-disconnect, 4 conductor, DC keyed

Excitation Voltage

Internally generated

Nominal Output Signal at Rated
MWF

Factory calibrated @ 0V= 0 Force; 10V=100% MWF

Non-destructive Overload

150% MWF

Ultimate Overload

300% MWF (typ) (500% for ratings > 25 lb-f

Maximum Voltage*, Base
(Ground)

50 Volts peak

Angular Deflection

0.01 inches Max. as measured at the far end of the sensing roll
with maximum load present. (Roll Journal deflection not included)

Operating Temperature Range

0 to 70 degrees C

32 to 158 degrees F

* 24V input circuit or +/- 10V output circuit