1 m12 mating connector, 2 electrical connections and wiring, Ating – Cleveland Motion Controls ULTRA ISC CANTILEVER TRANSDUCER CLTSCM REV AA User Manual

Page 16: Onnector, Lectrical, Onnections and, Iring, 1 m12

Advertising
background image

U

LTRA

S

ERIES

ISC

C

ANTILEVER

T

RANSDUCER

T

ECHNICAL

M

ANUAL

MAN-70445-0

R

EV

AA

2.1 M12

M

ATING

C

ONNECTOR

The M12 connector used on the Ultra Series ISC amplifier is a four-pin, DC keyed, male connector that
mates directly with the molded cordset offered by Cleveland Motion Controls. Table A lists the pin
numbers, signal, Function, wire colors and any notes that apply:

When mating the connector, align the keying
mechanism and pins so that they enter the
socket without you having to apply excessive
force. Use your fingers to sufficiently tighten
the coupling nut enough to ensure an adequate
seal and to discourage accidental loosening.

Figure 5 - Front View of M12 Connector

Pin #

Signal

Function

Wire

Color

Notes

1 24

VDC

Power Supply source
24 Vdc

Brown

+24 VDC
@ 50 mA max

2

+/- 10V OUT

Voltage Signal Output
Undamped bi-polar
tension signal

White

max. load 2 mA

3

0V RET

Power Supply Return

Blue

Must not exceed 25 volts from P.E.

4

COMMON

Signal Output Return

Black

Common for +/- 10V an analog
output. Must not exceed 25 volts
from P.E.

Table A M12 Pin Numbers and Cable Colors

If you choose to make your own cables or need to repair damaged connectors, you can purchase a separate mating
connector from Cleveland Motion Controls. To order, use CMC part number, X43-34338.

A fuse with a rating of 0.25A must be used in the fixed 24 VDC supply lead to limit potential damage to the
amplifier in the event of circuit malfunction. Example: Bussman GMA-250-R

Transducers (load cells) use strain gages which have limited insulation levels to ground (earth). This
requires that the COM terminals be

referenced

to ground (earth) to prevent damage to the transducers

(load cells).

2.2 E

LECTRICAL

C

ONNECTIONS AND

W

IRING

Refer to Figure 6 Installation Wiring Diagram for making the transducer to power supply and tension
controller connections. Make certain that:

 The cables do not interfere with the web path, and that they are away from power transmission,

gearing or other moving parts.

 You exercise care when routing the cables to avoid pick-up from noise-radiating power cabling

(motor armature leads, AC main wiring, etc).

8