System Set Up

The system must be set up before the Controller is used for the first time. The on screen prompts are very
easy to follow and will guide the user through the Controller system set up and commissioning. The
parameters can be easily changed later if necessary.

Press the SYSTEM SET UP key (called SET UP) to cancel an action or entry and return to the previous
screen. Press the CONFIRM key when finished with a screen to confirm the entries. If the CONFIRM key
is not pressed, the entries will not be saved to the memory and the existing parameters will be used.
Pressing CONFIRM will also exit that screen and return to the previous screen.

When entering Commissioning values and Product Parameters, some values are entered by the numeric
keys, some are entered by the +/- keys; this will be shown in the relevant sections later.
Use the Scroll keys to move the cursor up or down the menus. Enter a value using the ENTER key, the
cursor will move down to the next item. The CONFIRM key must be pressed to save values to memory.

When the Controller is switched on, the program is loaded, the company logos are shown briefly then the
Introduction screen below is shown. This sequence can be changed, see "Start in control screen" later.

CMC Advanced Digital Tension Controller

1. Control

2. Change Product

3. Product Parameters

4. Commissioning


Press 1 This will show the Control screen.

To exit the Control screen press SET UP.

Press 2 Enter a product number (1-20).

Product 1 is the default.

Press 3 Enter the SET UP password 1234 ( factory default ) and then press ENTER.

Product # Parameters

(SET UP = cancel)

Length outputs

Disabled, Enabled

Preceding length

( if a line encoder is available )

Full length

( if a line encoder is available )

PI stability setting *
Maximum trim

( Output trim only - NO )

Current tension set point

( The last tension value used )


An asterisk * indicates that a further menu will open if this item is selected.

Press 4 Commissioning password 5678 ( factory default ) and then press ENTER .

Commissioning Menu

1. Machine Parameters *

2. Calibrate tension *

3. Calibrate speed *

4. Adjust PI stability *

5. Change Passwords *

6. Diagnostics *


An asterisk * indicates that a further menu will open if this item is selected.