Machine parameters – Cleveland Motion Controls WebPro Intermediate Tension Controller MWP-12663 REV BA User Manual

Page 12

Advertising
background image

AO-70174

12

Revision BA

WebPro Intermediate Tension Controller

Machine Parameters

From the Commissioning Menu; press 1 to show the Machine Parameters screen

Machine Parameters

(SET UP = cancel)

changed
by

using

default
value

Language

English Deutsch Français Italiano Español

Unit system

S.I. / Metric kgf / Pound/foot / Percent

Controller application

Intermediate

Transducers before

Before / After

or after main motor

Output trim only

Yes / No

Output range

+/- 2V / +/- 10V

Start in control screen

No / Yes

Enable MAN/AUTO/OFF keys No / Yes
Dual tension range

No / Yes

Full scale (low)

Enter a value

Full scale (normal)

Enter a value

Minimum tension

3% minimum, 20% maximum

Output level bias 20%

maximum

Output level limit 100%

maximum

Set point ramp rate

1% per second, 100% per second

Display damping time

0.1 seconds, 3 seconds

Display precision

0.1, 0.5, 1, 5, 10


Digital inputs

MACHINE START

Disabled, 0V=OFF, 0V=ON

SELECT AUTO

Disabled, 0V=OFF, 0V=ON

SELECT MANUAL

Disabled, 0V=OFF, 0V=ON

SELECT OFF

Disabled, 0V=OFF, 0V=ON

DIAMETER HOLD

Disabled, 0V=OFF, 0V=ON

DIAMETER RESET

Disabled, 0V=OFF, 0V=ON

BATCH HOLD

Disabled, 0V=OFF, 0V=ON

ENABLE EXT SP

Disabled, 0V=OFF, 0V=ON


Show internal calibration *

No / Yes

Right transducer

Disabled, Enabled

Line tacho or encoder *

Disabled, Tacho, Encoder

+/-
+/-

+/-

+/-
+/-
+/-
+/-
+/-
numeric key
numeric key
numeric key
numeric key
numeric key
numeric key
numeric key
numeric key


+/-
+/-
+/-
+/-
+/-
+/-
+/-
+/-

+/-
+/-
+/-

English
S.I.

before

No
0-10V
No
No
No
5000N
5000N
6%
0%
100%
5%/sec
2 secs
1


Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled

No
Disabled
Disabled


An asterisk * indicates that a further menu will open if this item is selected.

Remember to press the CONFIRM key, otherwise the parameters will not be saved to the memory.

Note Start in Control Screen
The Controller is despatched with this item set to "No". We recommend that after all commissioning is
finished that this is then set to "Yes". When the Controller is now switched on, the program is loaded, the
company logos are shown briefly and then the Control or operating screen ready for use by the operator.

Note
The Controller will not accept an invalid input value which is outside the limits of operation. If an invalid
input is attempted the Controller will revert to the previous valid input.