Language, Unit system, Transducers before or after main motor – Cleveland Motion Controls WebPro Intermediate Tension Controller MWP-12663 REV BA User Manual

Page 13: Output trim only, Output range, Start in control screen, Enable man / auto / off keys, Dual tension range, Minimum tension

Advertising
background image

AO-70174

13

Revision BA

WebPro Intermediate Tension Controller

Language

(English, Deutsch, Français, Italiano, Español)

The default language is English. If changed, all text shown on the Controller will be changed to
that language and an extra item "5 - Translations" will be added to the Introduction screen.


Unit system

(SI (newtons), Kgf, pounds/foot, percent)

Select a unit system. All items which use units will be changed accordingly.


Transducers before or after main motor

(Before / After)

Select as required


Output trim only

(Yes / No)

Output trim only - No; this will combine the tension trim signal with the line speed signal to output
the speed demand to the controlled drive. This combined signal will always be positive.
Output trim only - Yes; this will output a +/- signal depending on the difference between the
measured tension and the tension set point.


Output range

(+/- 2V / +/- 10V

For Output trim only – Yes)

Select as required. Note, a line speed signal 0 to +10V to the controlled drive will usually be
required, the Controller trim signal inputting to an auxiliary direct speed input.


Start in control screen

(No / Yes)

The Controller is despatched from the factory with this set to "No". We recommend that after all
commissioning and set up is finished that this is then set to "Yes". When the Controller is now
switched on, the program is loaded, the company logos are shown briefly and then the Control or
operating screen is shown ready for use by the operator.


Enable MAN / AUTO / OFF keys

(No / yes)

When using the Digital Inputs to control the sequence of the system, this item should be set to
"No" to prevent accidental operation.


Dual tension range

(No / Yes)

Select "Yes" if required. Enter two values of tension. The (normal) value must be the same value
as entered during Calibrate tension. The (low) value should not be less than one third of the
(normal) value. Terminal TB4/11 is switched OFF when LOW is selected from the front panel.
See Digital Output Connections for more details.


Minimum tension

Enter a value, the minimum tension is 3%, the maximum is 20%. The system may not function
correctly and may be unsafe if it is operated at zero tension.

Advertising