WebPro Intermediate Tension Controller

Installation

The following parts are supplied:-
1. Controller, with software loaded for the application but requiring commissioning by the user.
2. Two keyhole mounting brackets.
3. Cable gland to be fitted to the rear cover and header connector kit for encoders.
4. Cabinet, if ordered.
5. Manual (this document).
Transducers and cables may also be supplied to complete the system

The Controller should be installed using 'best practice' and in accordance with all relevant regulations.
The Controller must be installed in a dry, non-hazardous location. A panel cut out 8.27in (210mm) wide X
7.01in (178mm) high is required. The Controller is 3.94in (100mm) deep, additional space for the cables
is needed.

The Controller is retained by two mounting brackets. Remove the four screws securing the mounting
brackets to the Controller. Insert the Controller into the cut out in the panel. Refit the four screws, attach
the mounting brackets to the Controller and tighten the two nylon screws to retain the Controller.

Cabinet Installation

The cabinet has rear mounting holes for M8 fixing. When
the Controller is supplied as a cabinet version the mains
supply is terminated inside the cabinet on a three way
terminal block. The incoming mains cable should be
securely fastened by the gland plate cord grip.

PCB Link Positions

The links LK1 to LK5 MUST be in the proper positions for
correct operation. It may be found more convenient to position the links before connecting the Controller.

LK1 Excitation Voltage Position B

This gives 5.6V for Cleveland-Kidder transducers

LK1 Excitation Voltage Position A

This gives 10V for ACDF and foil transducers

LK2 and LK3

IN

For Cleveland-Kidder transducers to complete the bridge

LK2 and LK3

OUT

For full bridge transducers, the bridges are complete

LK4 and LK5 Gain

Position A

Normal gain for Cleveland-Kidder transducers

LK4 and LK5 Gain

Position B

High gain for Cleveland-Kidder transducers

LK4 and LK5 Gain

Position C

Normal gain for ACDF and foil transducers

LK4 and LK5 Gain

Position D

High gain for ACDF and foil transducers


The high gain positions providing three times the normal gain are used if the transducers are oversized
and there is insufficient signal level for accurate calibration.

CUT OUT
210 X 178

155

380

ENTRY GLAND PLATE

LOCK

6 in.

(155mm)

2 in. (50mm)

11.

8 in

(300m

m

)

8.27 in. x 7.01 in.

(210x178mm)

15 in.

(380mm)

LK4

6

1 6

1

HD2

HD1

TB1

1

TB3

LK2

1

3

2

4 5 6

TB2

L

E

N

3

1 2

5

4

1

LK1

LK5

D

D

A

C

A
B
C

A B

B

VR2 SPAN

VR1 ZERO

TB4

LK3

TB5

3

2

4 5 6

8

7

9 10

14

11 12 13

15

10

9

6

5

4

2 3

8

7

13

12

11