MODEL CL600/605 INSTALLATION INSTRUCTIONS

STEP 2 (continued)

Fit remaining spindle to inside
- non code side.

STEP 3
Take the adaptor kit, item 13
on the contents page. Cut
the two M5 countersunk head
bolts to length to suit the
door thickness; i.e. door
thickness plus a maximum of
10mm (

3

/

8

”) (no more than

5mm (

3

/

16

”) should enter the

front plate). Hold the front
plate, with the three hole
neoprene seal, against the
door over the protruding
spindle. From the other side
of the door, fix the adaptor
plate to the front plate using
the two M5 countersunk bolts.
Before tightening up the fixings,
make sure that the spindle
hole is centrally positioned
over the follower. Do not use
excessive force.

STEP 4
Cut two of the long socket
head bolts to the required
length for your door.
Approximate overall length
should be door thickness plus
25mm (1”), to allow about
10mm (

3

/

8

”) of threaded bolt

to enter the front plate.
Place the neoprene gasket
over the adaptor plate. Use
the screw with the ‘T’ shaped
Allen key, to fix the back plate
to the front plate through the
TOP holes. Using the 20mm
(

3

/

4

”) socket head bolt fix the

back plate through the
BOTTOM hole to the adaptor
plate. Do not use excessive
force.
STEP 5
Check that the lever handles
are correctly fitted for the
hand of door. To change the
hand of a lever handle, loosen
the grub screw with the small
Allen key, reverse the lever
handle and fully tighten the
grub screw.

6

STEP 6
Before closing the door, enter
the code and check that the
latchbolt retracts when the
lever handle is depressed.
Now check the operation
of the inside lever handle.
If there is any binding of the
handles or latch then loosen
the top and bottom bolts and
reposition the plates slightly
until the correct position is
found, and then re-tighten
the bolts.