5.3 Connecting the REMOTE Connector

You can force the routing of one of the 2 inputs to the VGA output by remote

control. To do so, connect the appropriate REMOTE input terminal block

connector pins to a dry contact switch

1

. For example, as Figure 4 illustrates, to

route REMOTE IN 1 to the VGA output, connect PIN 3 to PIN 2. To route

REMOTE IN 2 to the VGA output, connect PIN 1 to PIN 2. Do not connect both

the REMOTE IN 1 and the REMOTE IN 2 to PIN 2 simultaneously.

Route input 1 to the output,

by attaching PIN 3 to PIN 2:

Route input 2 to the output,

by attaching PIN 1 to PIN 2:

Figure 4: Remote Terminal Block Connector

When both VGA IN 1 and VGA IN 2 are connected, the signal from VGA IN

1 routes to the output. However, you can force the routing of VGA IN 2 to the

output by attaching PIN 1 to PIN 2. If no input is present on VGA IN 1, you

can even force the routing of the output from VGA IN 1 (displaying a blank

screen) by attaching PIN 3 to PIN 2.

1 Note that the connection should be permanent, since the CSW-VGA211 will revert to an automatic switcher when the
connection is removed