Option b switches, Baud switches – CTI Products NCB/AY with Serial Interface User Manual

Page 16

Advertising
background image

CTI Products, Inc.

NCB-AY User Guide

2. Setup and Operation

10

If OPTION A Switch 5 is DOWN, dynamic determination of the domain/subnet/node number by a
Network Management Tool is allowed.

OPTION B Switches

OPTION B switches set the Serial Port Handshaking options.

1. PORT 1 CTS sense..........................Disabled

Enabled (Normal)

2. PORT 1 DSR sense .........................Disabled

Enabled (Normal)

3. PORT 2 CTS sense..........................Disabled

Enabled (Normal)

4. PORT 2 DSR sense .........................Disabled

Enabled (Normal)

DOWN

UP

1

2

3

4

ON

CTS/RTS flow control can be used to pace the transmission of individual bytes between the NCB and a
connected device.

DSR/DTR handshaking informs the NCB that a connected device is active. If the channel does not directly
support DSR/DTR handshaking, DSR must be strapped back to the (always active) DTR output signal.

When enabled, the operation of CTS/RTS and DSR/DTR is as follows:

Signal

Direction

Function

CTS

Input to NCB

Active when the connected device is ready to accept characters from NCB.

This signal is driven by the RTS signal of the connected device.

RTS

Output from

NCB

Active when NCB is ready to accept characters from the connected device.

This signal is received by the CTS signal of the connected device.

DSR

Input to NCB

Active when a connected device is functioning.

This signal is driven by the DTR signal of the connected device.
If driven inactive, NCB front panel “ERR” LED will flash quickly, and NCB
will not communicate with this device.
If DSR signal is not available from connected device, strap to DTR output.

DTR

Output from

NCB

Always driven active by NCB.

BAUD Switches

“BAUD 1” and “BAUD 2” switches correspond to “PORT 1” and “PORT 2” connectors and allow either
disabling the port for use or enabling it at a specific baud rate.

Position

Function/Baud Rate

0

Disable Port

1

1200 Baud

2

2400

3

4800

4

9600

5

19200

6

38400

7

57600

8

115200

8 9

7

A

B

C

D

E

F

0

1

2

3

4

5

6

8 9

7

A

B

C

D

E

F

0

1

2

3

4

5

6

BAUD 1

BAUD 2

Advertising