1. Introduction

7

CMD Button

This button can be used to temporarily enable the Auto Answer function in Dial-up mode. This is useful if
Auto Answer mode has been inadvertently disabled on a remote NCB. When this occurs, and a connection with
this remote unit is broken, it will no longer automatically answer an incoming call. To re-enable Auto Answer
mode, proceed as follows:

Press and hold the “CMD” button on the remote NCB

Press and release the “RESET” button on the remote NCB.

Wait until the “PWR” LED begins to flash on the remote NCB, then release the “CMD” button.

These steps will temporarily enable Auto Answer mode for the remote NCB for one incoming call. Use the
NCB/Plug configuration plug-in, NCBCON, or explicit messages to re-enable Auto Answer mode for future
connections.