Appendix E. Troubleshooting

41

Does not illuminate on

originating NCB when
using a Dial-Up line and a
connection is attempted.

1. DIAL command is not being sent

correctly to originating NCB.

2. Defective modem.

1.

Verify that the originating NCB is
receiving a proper DIAL command.

2.

If “OH” LED does not illuminate, call
CTI Products, Customer Support (+1-
513-595-5900), to arrange to return
unit for evaluation/repair.

Illuminates only briefly (less

than 5 seconds) on
originating NCB when
using a Dial-Up line and a
connection is required.

Dial-up line is not operating to the telco

switching equipment. (While initiating a
dial-up connection, and with a handset
connected to the AUDIO connector of
the originating NCB, the dial tone can
not be heard.)

Contact dial-up line provider for line status.

Table E4

If the CD LED . . .

REASON

CORRECTIVE ACTION

Illuminates within 45 seconds

of resetting (“OH” LED is
already illuminated) when
using a Leased-Line.

Normal operation indicating the modem is

connected to another NCB’s modem.

Go to next Table.

Illuminates within 45 seconds

of illumination of “OH”
LED on originating NCB
when using a Dial-Up
line
.

Normal operation indicating the modem is

connected to another NCB’s modem.

Go to next Table.

Does not illuminate within 45

seconds of resetting (“OH”
LED is already
illuminated) when using a
Leased-Line.

1. OPTION A Switch is not set correctly.





2. Incorrect 4-wire leased-line connections.

3. Leased-line is not operating.

4. Defective modem.

1a. Verify OPTION A Switch 1 is down

for the originating NCB, and up for
the answering NCB.

b. Verify OPTION A Switch 7 is up (-

10dBm transmit level) for normal
operation, or down (-16 dBm transmit
level) for back-to-back operation (on
both NCB’s)

2.

See “Appendix G. Modem Notes”.

3.

Contact leased-line provider for line
status.

4.

Call CTI Products, Customer Support
(+1-513-595-5900), to arrange to
return unit for evaluation/repair.

Table E4 continued on next page

Advertising