PIPInG ConfIGUraTIons & ConneCTIons

Piping configurations for Liquid Controls mechanical air

and vapor eliminators are determined by two factors,

the presence or absence of a valve in the meter system

and the presence or absence of bypass ports and a

limited bleed valve plate in the mechanical air eliminator

assembly.

If the meter system has an air check or differential valve,

the air or vapor eliminator and the valve must be piped

together. If no air check or differential valve exists, you

must either plug one of the vent ports (Figure 2) or pipe

both vent ports to the storage tank (Figure 3).

Air eliminator models cast without bypass ports cannot

be assembled with a limited bleed valve plate at the

Liquid Controls factory. To retain the pressure control a

limited bleed valve plate provides, a limited bleed tee

assembly must be installed in the piping between the air

eliminator and the valve (Figure 4).

Under normal circumstances, it is irrelevant which vent

port is piped to the valve and which vent port is piped

to the storage tank, but there is one exception: air

eliminators with an increased venting capacity valve

plate. These include part numbers A8201, A8198,

A8190, A8188, and A8183. When installing these air

eliminators, the increased venting valve plate should be

piped to the storage tank, and the limited bleed valve

plate should be piped to the valve. The limited bleed

valve plate is easily indentified by the notch in the top of

the plate (see below).

Limited Bleed Valve Plate

To Air Check/Differential Valve

To Supply/Storage Tank

PIPInG WITh valve

PIPInG WITh no valve

To Supply/Storage

Tank

To Air Check/Differential Valve

To Supply/Storage

Tank

PIPInG WITh valve

To Supply/Storage Tank

PIPInG WITh no valve

The piping configuration for each air and vapor

eliminator series is shown in the bill of materials.

Figure 1

Figure 2

Figure 3

Figure 4

Standard Valve Plate

When using an electronic valve, product may become

trapped between the vapor eliminator and the valve.