Installation, Retrofit installations – Liquid Controls Optical Air Eliminator US Patent 7000628 Refined Fuels Applications A8981 & A8981A User Manual

Page 7

Advertising
background image

7

Installation

Step 2 - Mount the Optical Air Eliminator

Depending on the strainer being used, the optical air elimina-

tor may be fastened to the strainer/air eliminator in any of four

90° rotational increments. Select the most suitable orientation

for ease of final installation of wiring and vent piping.
Fasten the optical air eliminator to the strainer using the

four bolts and washers. Tighten the bolts to a torque of 27

lbf-ft (37 Nm).

These retrofit instructions will show a system using a

Hi-Cap strainer/air eliminator; however, the optical air

eliminator may also be installed on other LC strainer as-

semblies used for refined petroleum products.

Step 1 - Remove Old Air Eliminator and Baffel Cup

After the internal pressure has been relieved from the system

and the assembly drained of liquid, remove the four bolts

and washers used to fasten the old air eliminator to the top

of the strainer. Inspect the O-ring and replace if necessary.

Step 3 - Connect the Vent Piping/Tubing

This connection is ½” NPT. Remove the pipe thread protector

and then connect the piping/tubing to the vent port. This pip-

ing typically connects directly to an overflow tank on a truck.

Step 4 - Wire the Solenoid and Sensor to the Register

Wiring instructions begin on Page 9.

Retrofit Installations

Figure 9: Orient the Optical Air Eliminator

Figure 10: Fasten the Optical Air Eliminator

Figure 8: Remove old Air Eliminator

Advertising