Clean the components – Magnum Venus Plastech Pro Gun CPD_PRTM - 1:1 User Manual

Page 33

Advertising
background image

1:1 Classic Pro Gun Manual

Rev. 05/2012

Page | 33




Note: Be careful not to drop the chrome balls located inside the trigger retainer.
If your gun is used for gel coating or wet out, there will be no balls in the trigger
retainer.

4.

Remove the balls (03198) in the trigger retainer by inserting a small scribe
between the two o-rings and into each side hole of the retainer.

5.

Remove the two o-rings (O-U-109) on the trigger retainer.

6.

Remove the two o-rings (O-U-011) on the spool assembly.

Note: The spool assembly does not disassemble.

Clean the Components

Discard the used seals and o-rings and clean the remaining parts in solvent.

Check the items to be reused for damage or wear.

02970 (COTTER PIN)

O-U-011 (O-RING)

F-FS-540-08 (SCREW)

58624-1 (HANDLE)

58628-1 (TRIGGER BUSHING)

58647-1 (VALVE ASSY)

03198 (BALL)

O-U-109 (O-RING)

O-D-010 (O-RING)

58648-1 (RETAINER)

58625-1 (TRIGGER)

02647-3 (SCREW)

58629-1 (GUIDE PIN)

58629-3 (PIN -NO LOCK)

58629-1-SS (GUIDE PIN

– SS)