Flush Valve Assembly:
1. Place the O-ring on the Flush Valve Button.
Note: If using O-ring part number O-K-008 (O-ring is used on the Flush Button),
you do not need to replace the O-ring unless it is showing obvious signs of wear
or damage. This O-ring is specially designed for use with all solvents.
2. Insert the Spring onto the Flush Valve Button.
3. Push the Button and Spring into the Flush Valve Body.
4. Place the O-ring on the Flush Seal Body.
Note: Different O-rings are used on the two assemblies TLN-FV-1000 & TLN-FV-
1000-INT
5. Insert a Flush Seal Body into the end of the Flush Valve Body and screw it onto the
Button.
6. Place a Flush Valve Seal on the Flush Valve Body.
7. Install the Flush Valve Body into the Flush Valve Neck.
8. Install the Split Seal onto the Flush Valve Body.