Resin Problems - continued

Problem

Possible Cause(s)

Recommended

Solution(s)

Resin leaking from the front of
the Gun block / Spray Tip

Damaged or Dirty Ball in the
Material Cartridge

Clean or Replace the Material
Ball as necessary

Damaged or Dirty Material Seat
in Material Cartridge

Remove the Material Cartridge

check and clean ball seat

Actuating Rod holding the Ball
open

Check that the Actuating Rod is
moving freely and not being
pressed down by the handle

Stuck or Damaged Actuating Rod Check and repair Actuating Rod

as necessary

Damaged Compression Spring

Check and replace the
Compression Spring in the
Material Cartridge

No Resin from the gun

Blocked Spray Tip

Clean or replace the Spray Tip

Actuating Rod not opening
material ball

Check the Actuating Rod for
damage and check the Material
cartridge and ball.

Gun Head porting blocked

Check and clean gun head
porting

Blocked resin hose or fitting

Be sure the resin hose and fitting
is not block or damaged

Resin pump not working correctly Repair the Resin Pump as

necessary for proper operation

Resin Return Ball valve open

Close the Ball valve located
below resin filter.


Flush Problems

Problem

Possible Cause(s)

Recommended

Solution(s)

Solvent leaking around the Flush
Neck

Flush Body loose

Tighten Flush Valve Body a little
into the gun block

– do not over

tighten

Damaged Split Seal

Replace Split Seal

Dirty or damaged gun block

Check and clean gun block
around flush port

Solvent leaking between the
Flush Neck and Flush Body

Flush Body loose

Tighten Flush Valve Body a little
into the gun block

– do not over

tighten

Damaged Flush Valve Seal

Replace the Flush Valve Seal

Damaged Flush Valve Body or
Flush Valve Neck

Check the Flush Valve Body &
Neck for scratches or damage

Solvent leaking around Flush
Button

Damaged O-ring on the Flush
Button

Replace the O-ring on the Flush
Button. Make sure the O-ring is
compatible with the Solvent

Damage Flush Valve Body

Replace the Flush Valve Body

Solvent leaking around the Barb
fitting

Loose Barb fitting

Tighten the Barb fitting into the
flush Neck

Damaged Seal

Replace the nylon Seal