6-9

March 31, 1999

6.4

I/O unit/E

Figure 6-3: Two I/O units/E

6.4.1

Inserting cartridges

New cartridges are inserted in the AML/J through the I/O unit.

Step 1

Press the button on the I/O unit

The button lights up green. On release by the robot control the shutter
is unlocked.

Step 2

Open the shutter of the I/O unit

Step 3

Pull out the slide of the I/O unit

Step 4

Remove the magazine

Step 5

Insert the cartridges in the magazine. Pay attention to the cor-
rect position.

• Tape head to the right
• Label to the front

Step 6

Put the magazine back in the I/O unit

Step 7

Push the slide back in

Step 8

Close the shutter of the I/O unit

The AML/J locks the shutter of the I/O unit .
According to configuration the robot checks the magazine (barcode or
empty place) on the cartridges.

Step 9

Move the cartridge with the aid of the host software into the
archive
(exception: foreign mount cartridges)

The cartridges are brought into the archive.

Door lock

Requirement button

Shutter