Care – Bosch BSG82212 schwarz Bodenstaubsauger Beutel ergomaxx professional 2200 W User Manual

Page 17

Advertising
background image

12

Replacing the active carbon filter*

If your vacuum cleaner is fitted with an active carbon filter, this
must be replaced once a year.

Figure
Ⅲ Remove the active carbon filter and dispose of it with

the household rubbish.

Ⅲ Insert a new active carbon filter. (See Figures 21, 22, 23

for changing the filters)

Care

Always switch off the vacuum cleaner and disconnect the
power cord from the mains before cleaning the appliance.
The vacuum cleaner and plastic accessories can be cleaned
with a commercial plastic cleaner.

!

Do not use a scourer, glass-cleaning agent or all-pur-
pose cleaning product.
Never immerse the vacuum cleaner in water.

The dust compartment can, if necessary, be cleaned with a
second vacuum cleaner or simply wiped with a dry cloth or
dusting brush.

Subject to technical modifications.

24*

Cleaning the motor protection filter

The motor protection filter should be cleaned regularly by
knocking out the dirt and rinsing.

Figure
Ⅲ Open the dust bag compartment lid (see Figure 17).
Ⅲ Pull out the motor protection filter in the direction of the

arrow.

Ⅲ Clean the motor protection filter by tapping it.
Ⅲ If it is very dirty, the motor protection filter should be

rinsed.
The filter must then be left to dry for at least 24 hours.

Ⅲ After cleaning, insert the motor protection filter into the

appliance as far as it will go and close the dust bag
compartment lid.

You can obtain a new motor protection filter on request as
a spare part from the after-sales service. (see Spare parts,
page 13 )

Changing the micro-hygiene filter*

The micro-hygiene filter should be replaced with every new
replacement filter pack (after 5 dust bags) and at least
once a year.

Figure
Ⅲ Press the locking tab in the direction of the arrow to

unlatch the exhaust grille and open it.

Ⅲ Unlatch and remove the filter frame by pressing the tab

in the direction of the arrow.

Figure
Ⅲ Remove the foam and micro-hygiene filter.
Ⅲ Dispose of the micro-hygiene filter and fit a new micro-

hygiene filter.

Ⅲ Clean the foam and replace in the filter frame.

If you have used the vacuum cleaner for fine dust particles
(such as plaster or cement), clean the motor protection fil-
ter by tapping it and, if necessary, replace the motor protec-
tion filter and the micro-hygiene filter.

Figure
Ⅲ Slide the filter frame under the two retaining ribs and push

in the direction of the arrow until it engages.

Ⅲ Close the exhaust grille.

Replacing the Hepa filter*

If your vacuum cleaner is fitted with a HEPA filter,
this must be replaced once a year. (See figures 21 and 23 for
changing the filter)

23

22*

21

20

en

Advertising