10. This set up is only required if the dock leveler is a

CLEAN PIT® model.

A. Burn or grind off welds where the maintenance

prop and hoist cylinder trunnion box are welded
to any steel imbedded in the pit.

B. Refer to the CLEAN PIT Installation Instruction

in the dock leveler owner’s/user’s manual. The
center angle and the front angle, which were
removed during the original installation, are to
be reinstalled.

NOTE: If the angles are supplied by Systems, Inc.,
the angles are shipped with the truck restraint pan
unit.

11. Set the leveler platform in the cross traffic position

(the lip fully folded, inside the lip keepers, and the
platform level with the dock floor).

12. Place a shipping band through the lip hinge and

around the front frame angle of the leveler. Secure
the banding. The banding is to secure the frame
angle to the platform when the leveler is removed
from the pit.

13. Burn or grind all welds where the top rear frame

angle of the dock leveler is welded to the rear pit
curb angle.

14. Remove Dock leveler from the pit using the lifting

brackets.

15. Cut pit for the truck restraint pan as indicated on

the Pit Drawing.

16. Cut out or chip to accommodate 3/8” x 16” x 16”

hoist cylinder trunnion plates (S) which must be
imbedded into the pit floor as shown on the pit
drawing. If the existing dock leveler is a CLEAN
PIT model, it may be possible to reuse the existing
plate. On eight foot long dock levelers the plate is
an integral part of the truck restraint and a separate
plate is not required. See table on page 15

17. Install restraint pan into the pit. Insert spreader bar

into pan to reinforce during concrete pour. Make
sure the pan’s square and flush with the pit floor
and front dock wall.

18. Pour concrete around the truck restraint pan

and Hoist cylinder trunnion plates(s) that to be
imbedded in the pit floor in the plate is separate
from the pan.

19. Allow sufficient time for the concrete to set.

20. Assembly truck restraint (only required if pan was

shipped separately).

A. Remove all trunnion keepers.
B. Grease cylinder truinons.
C. Install cylinders.
D. Install all trunnion keepers and prox switches
See adjustments pg 28

21. Reinstall the dock leveler as indicated in the

dock leveler manual. Do not complete electrical
connections until all welding is complete.

22. Modify dock leveler frame as needed per “Dock

Leveler Modification Drawing”.

23. Install all hydraulic hose and fill system with

approved hydraulic oil. See page 26

24. Install outside signs and lights

25. Finish all electrical connections.

26. Adjust and test leveler and restraint operations.