ADJUSTMENTS

Adjust PowerHook Operating Range

1. Adjust the upper vertical limit of PowerHook

operating range if necessary.

A. Locate the hook cylinder assembly and the

hold down cylinder assembly. The length of
the threaded eye on the hold down cylinder will
determine the upper vertical limit of the hook
movement.

B. Disconnect the Hydraulic hose from the hold

down cylinder. Cap off the open fittings to
prevent fluid loss and to prevent contamination
from entering the system.

C. Remove the keepers from the hold down

cylinder trunnion.

D. Lift up on the hook cylinder. This will allow the

hold down cylinder to exit the trunnion.

E. Support hook cylinder, loosen the jam nut

that is on the threaded eye of the hold down
cylinder.

4111-0010 — Nov 2010

28

Threaded Eye
and Jam Nut

Hose Port

Figure 10

Position cylinder trunnions

Clock Wise

Counter clock Wise

Hook Cylinder

Figure 11

Hook cylinder trunnions