Programming – Poweramp POWERHOOK SERIES User Manual

Page 47

Advertising
background image

4111-0010 — Nov 2010

45

Twido PLC

E-Prom

ISSUES FOR PROGRAMMING.
• Error light is flashing, PLC is either missing or

damaged.

• Update to newer program.
• Installation of new un programmed PLC.

MATERIAL REQUIRED.
You will receive two (2) E-proms.
• Blank run E-Prom.
• Program Specific E-Prom.

INSTALLATION
1. Turn power off power. (remove existing E-Prom if

present).

2. Insert new “Blank Run” E-Prom.
3. Turn power on for 30 seconds.
4. Turn power off for 10 seconds repeat cycle 3 times.

• Insert program chip (program specific)
Repeat steps 1,3 and 4. Allow light sequence to
complete flashing. Run light should be on STEADY not
flashing

. Error light should NOT be on. Check for proper

input and out put lights on the PLC.
If not, repeat steps 3 and 4 until PLC responds properly.
If the PLC does not accept the program or if questions
contact the “Tech Service Department” at 800-643-
9424.

Note: The PLC will maintain the program even if the
power is turned off.

Prom Location

PROGRAMMING