GENERAL INFORMATION

DESCRIPTION OF OPERATING MODES

A.

"NORMAL" OPERATING MODE
Used to operate the POWERHOLD restraint to engage the truck ICC bar. An
auto-raise cycle will be activated by momentary pressure on the "LOCK" push
button (Note: Pressure on the "LOCK" push button must be maintained until
the inside lights change from red to amber). An AUTO-LOWER cycle will be
activated by momentary pressure on the "UNLOCK" push button. If no truck
ICC is engaged, the unit will automatically return to the stored position and an
alarm will turn on. The inside and outside signal lights will automatically
change as the unit reaches different positions in the raise and lower cycle.

B.

"BYPASS" OPERATING MODE
Used when the truck does not have a serviceable ICC bar or if operating the
POWERHOLD restraint may damage equipment on the truck. The restraint
cannot be operated in this mode. The inside lights are amber and the outside
lights are red at all times in this mode. The truck wheels must be chocked
when operating in this mode.