For interconnection of smoke alarms to Fire Panel or Auxiliary de-

vices, use only LIFESAVER Isolation Relay Model RK10A/9.

6.1.16 This Smoke Alarm can be interconnectable only with other LIFESAVER

models of Smoke Alarms; whether it be of Ionisation or Photoelectric design.
Interconnection with other brands may cause damage or result in a shock or
fire risk.

6.1.17 When interconnected all Smoke Alarms will sound upon activation.
6.1.18 WARNING: This alarm cannot be operated from power derived from a

square wave, modified square wave or modified sine wave inverter. These
type of inverters are sometimes used to supply power to the structure in
off grid installations, such as solar or wind derived power sources. These
power sources produce high peak voltages that will damage the alarm
.

6.1.19 PSA recommend the smoke alarms to be installed on its own subcircuit to

avoid false alarms and nuisance chirping that may be caused by electromag-
netic interferences from other electrical equipment.

6.2 Mounting Instructions:

6.2.1 Separate Smoke Alarm from mounting base by sliding cover (in direction of

arrow) with one hand on the back of the mounting base and one hand sliding
Smoke Alarm(See Fig. 1).

6.2.2 Connect supply cable to terminal block and fix terminal cover.
6.2.3 Align and slide smoke alarm up onto mounting base (Fig. 2) then slide in the

reverse direction of arrow to ensure proper connection.

6.2.4 Switch on power and check the green light on alarm cover. It should be lit

when mains power is switched on indicating that the smoke alarm is properly
connected to the mounting base.

6.2.5 Secure Tamper Locking Pin (supplied) to smoke alarm.

6.2.6 Test alarm by pressing Test button.