7. OPERATION, TESTING AND MAINTENANCE

7.1.4 Green LED

7.1.4.A AC Mains-ON Indicator: indicates that the unit is operating with AC

power. If this LED goes out, it indicates that the AC power is off.

7.2 False Alarm Hush Control Feature:

Note: Dense smoke will override Hush control feature and

sound a continuous alarm.

7.2.1 This smoke alarm has the capability of being temporarily

desensitized for approximately 5 minutes.

7.2.2 The smoke alarm is desensitized by pressing the“ H U S H ”

button on the smoke alarm cover.

7.2.3 After pressing the“ H U S H ” button, the alarm will silence

immediately and “ c h i r p ”every 32 seconds for approximately 5
minutes to indicate the alarm is in the temporary desensitized condi-
tion.

7.2.4 The smoke alarm will automatically reactivate after approxi-

mately 5 minutes and sound the alarm if particles of combustion
are still present.

7.2.5 The “HUSH” feature may be used repeatedly until the air has

cleaned.

WARNING: Before using the alarm HUSH feature, identify

the sour

ce of smoke and be certain that a safe condition

exists.