7. MAINTENANCE & SERVICE INSTRUCTIONS

.
These instructions are for trained pump
service engineers.

Where instructions in this section are
followed by (LH) or (RH) this indicates either
the left hand or right hand side of the unit
looking from the pump (towbar) end

7.1 Preparation for Maintenance

Electric Shock & Accidental Starting
Hazard
ISOLATE the equipment from any
mains

supply

connected

before

any

maintenance work is done.

For diesel engine driven pumps disconnect
the negative battery lead to prevent
inadvertent starting.

To avoid the possibility of maintenance
personnel inhaling dangerous fumes or
vapours.

It

is

recommended

that

maintenance work be carried out away from
the pump location by removal of the pump
unit to a suitable maintenance area.

No special tools are required for dismantling
and re-assembling, however, it is important
to ensure the suitable lifting equipment is
available and that the work is carried out in a
clean area.

7.2 Pump Bearings

The pump shaft runs on three bearings: a
roller bearing on the impeller end of the shaft
and a pair of angular contact bearings on the
drive end of the shaft. These bearings are
grease lubricated.

BRGHSGA

DRIVE END
GREASE
NIPPLE

PUMP END
GREASE
NIPPLE

Grease is applied through two grease
nipples, one for the roller bearing and one for
the pair of angular contact bearings located
on the left side of the bearing bracket. Do
not over grease. Ten strokes (15 grams) of a
hand held grease gun at the specified

intervals are sufficient.

7.3 Mechanical Seals

The mechanical seals are cooled and
lubricated by oil. The oil reservoir is mounted
on top of the non-return valve cover. The
system oil capacity is approximately two
litres. The bottle should be filled to the MAX
mark when the unit is cold.

Only use oil of the correct grade
(see Technical Data section).

7.4 Fuel Filler Gauge

Located in neck of fuel filler. Inspect for
debris. Remove and clean if necessary.




7.5 Coalescer Maintenance

Daily, check the oil level in the coalescer
sump. If the level has risen, check for water
contamination, drain off any water present
and top-up the oil to the level between the
marks on the dipstick. Water is removed by
means of the drain tap fitted to the side of
the coalescer sump.

7.6 Coalescer Filter Element Replacement

Coalescer filter elements must be replaced
after the first 500 hours or one month of
operation of a new vacuum pump, after
which they need to be replaced only when
the

inside

surface

becomes

heavily

discoloured i.e. black or dark brown. These
elements cannot be cleaned, new elements
must be fitted when required thus:

NEWC

OAS3

REMOVE THE COALESCER LID

UNSCREW THE
ELEMENT CAPS

LIFT ELEMENTS
AND REPLACE

REPLACE THE
COALESCER
LID

Ensure that the seals at the top and bottom
of each filter element are fitted correctly.

ATTENTION

FU

EL

FI

LT

ER

NEWC

OAS1

OIL FILLER
& DIP STICK

EXHAUST
PORT

(FAR SIDE)

COALESCER
LID

WATER DRAIN TAP

FILTER
MESH

OIL
SCAVENGE
PIPE

OIL
FEED
PIPE

OIL
FILTER

Advertising