Pumping reduced with surging:

5.5.4.

Check that the impeller is clear of
debris and remove debris, if present.

5.5.5.

Check the non-return valve is clear.


Pump fails to prime after starting:

5.5.5.

Check suction hoses for leaks and
ensure all hose fittings are air tight.

5.5.6.

Check that volute drain cock is
closed.

5.5.7.

Check that the non-return valve is
free of debris and can seal when
closed.

Engine stops:

5.5.8.

Check engine fuel level, and refuel if
necessary.

5.5.9.

Check warning indicator lamps and
correct any faults indicated.

5.5.10.

Check the trip switch and reset.
Repeated resetting of the trip switch
indicates an electrical fault, call
service engineer.

6. PUMP MAINTENANCE CHART

Highlighted tasks in italics below are to be done by the pump operator, other tasks by the pump service
engineer. For engine maintenance periods refer to the engine operators handbook included within the
pump documentation pack.

PERIOD

TASK

After first 500
hours of
operation

IMPORTANT (Also required 500 hours after fitting a new vacuum pump)
Replace the four coalescer filter elements.
Replace the coalescer oil and oil filter.

Daily

Check and top up the coalescer oil. Check and top up the engine oil.
Check and top up the diesel fuel.

Check the fuel filter and drain off any

water.
Check and top up the mechanical seal oil reservoir level.

Check and top up the engine cooling water.

Weekly or
100 hours

Check security of all fasteners & fittings. Check battery electrolyte level.
Check condition of battery connections. Check security of battery mountings.
Drain any water from coalescer.

Check visually for leaks.

Monthly or
500 hours

Check priming tank air filter, clean if dirty.

Check fuel filler filter.

Check vacuum pump belt tension.

Check for contamination of coalescer oil

Check the condition of the vacuum pump belts and renew if necessary.
Grease the drive end pump bearings with 15grms of grease.

6 monthly or
3000 hours

Check and clean the level sensing probes.

Check electrical connections.

Check condition of non-return valve & flap.

Replace the four coalescer air filters.

Change mechanical seal coolant/lubricant.

Change coalescer oil and oil filter.

Check the vacuum pump drive belts and renew if necessary.
Clear and clean or replace the small air filter on the solenoid valve.

9 monthly or
4500 hours

Grease pump end pump bearing with 15 grams of grease.

Annually or
6000 hours

Check condition of impeller and wear plate.
Check and replace the coalescer & priming tank knitmesh filters.

Bi - annually
or 12000 hrs.

Repack pump bearings with grease.