Operators Instructions for

AUTOPRIME Q Range Pump Unit

Manual No/Rev

W72-008E / 9

Our policy is one of continuous improvement and we reserve the right to alter specifications at any time

Page 11 of

18

Do not over tighten the retaining
knob as this will distort and crush
the filter element
.

7.7 Coalescer Filter Mesh

Every year or more frequently if the pump
has been operating in a dusty atmosphere or
when the coalescer oil has become dirty, it is
recommended that the priming tank filter
mesh is replaced.

NEWC

OAS2

COMPRESS THE
FILTER & PUSH
UPWARDS INTO
PLACE. RETAIN
WITH MESH AS
SHOWN

Drain the coalescer oil, disconnect the oil
feed pipes and remove the coalescer lid and
the coalescer element housing complete
with the filter elements. Remove the mesh
retaining the filter to give access for removal
of the knitmesh filter.

It is recommended that a new gasket is fitted
before re-fitting the coalescer element
housing.

The oil feed pipes should be cleaned in a
similar manner and blown through with an air
line.

7.8 Non-Return Valve

The non-return valve should be checked
regularly for freedom of movement, absence
of debris and good seating. The valve seat
should also be checked for damage or wear.

The flap type non-return valve is built in to
the pump casing and located under a cast
cover on top of the pump behind the
discharge flange. It consists of a hinged
rubber disc resting on a seat machined onto
the volute. The disc and seat can be
examined through the discharge flange once
the quick release hose connection is
removed. Check that the disc sits cleanly

onto the seat and that nothing is trapped
between the hinge and the casting (both
above and below). Check that the disc is not
worn or torn and that the seat is not
excessively

pitted.

A

more

detailed

examination can be undertaken by removing
the cover on top of the valve. Replace the
cover gasket when refitting the valve cover.

NRV

1

FLAP

DISCHARGE
FLANGE

FLAP TYPE
NON RETURN
VALVE

ACCESS
COVER

FLAP
OPEN

FLAP
CLOSED

7.9 Vacuum Pump Belt Tension

To adjust belt tension, loosen the pivot and
locking bolts and using a spanner on the
adjustment aid, slide the pulley outward.
When the correct belt tension is obtained re-
tighten the locking bolt and the pivot bolt.

5kgs
6mm

1

9

0

m

m

PIVOT
BOLT

LOCKING
BOLT

1/2" SQ
ADJUSTMENT
AID

BELTENS1

Do not under-tension belts under
any circumstances
.

7.10 Vacuum Pump Belt Replacement

Remove the vacuum pump drive guard if
fitted.

Slacken and remove the belt tension device
by removal of the pivot bolt and the locking
bolt.

From the main pump drive coupling, remove
the three screwed pins from the rubber
coupling to give a gap between the engine

ATTENTION

ATTENTION

Advertising