Standard PL-1746 Series Features

2

Non-Volatile Memory - configurations
saved when power is interrupted.

Absolute position with high resolution
(Up to 4096 increments per revolution)

48 available programs - active pro-
grams selected through the backplane
or via the Electro Cam Corp. 6400 se-
ries keypad/display.

Complete module status available
through the backplane.

Up to 32 PLS output channels avail-
able through 1746 backplane. All
channels are available to use either
with the Electro Cam Corp. I/O rack
(High Speed/Real World), or any 1746
discrete output module.

Real world, high speed I/O available
via either an 8 input/8 output, or an 8
input/16 output external DIN mount
rack.

Up to 32 digital plus 2 analog outputs
available.
(Requires two racks, 16 I/O per

rack)

SLIMLINE™ module outputs: AC, DC

PL-1746-C01 Plug-In Module

PS-4108-13-L08 & PS-4108-13-L16 I/O Racks

The PS-4108-13-L08 and PS-4108-13-L16 I/O racks
provide inputs, analog outputs, and digital power
outputs (requiring SLIMLINE™ solid state relays) for
the PL-1746-C01 PL

µ

S plug-in modules.

Automatic leading & trailing edge speed
compensation - to advance/retard out-
put channel timing to compensate for
ON/OFF delay in valves and other de-
vices.

2 levels of motion detection - to enable/
disable speed critical machine func-
tions.

4 timed outputs for controlling time criti-
cal functions initiated by position.

Output Groups and Operating Modes
- allows high speed logic to be done in
the PLS, separate from the PLC scan.

Able to connect up to 2 Electro Cam
Corp. Model 6400 keypad/displays for
remote adjustment.

Ability to access user selected param-
eters while operating in an Allen-Brad-
ley remote I/O chassis.

Resolvers

Electro Cam Corp. Resolvers are de-
signed for rugged industrial applications.
They feature dual bearing construction
(except the 5212 model), and come in a
variety of mounting styles and shaft
sizes. Some resolver configurations are
shown here.

See Price List (Lit. #202) for complete
listing of part numbers and specifica-
tions.

PS-5275-11-ADS

Foot Mount

• 3/4" Shaft

• Top side, right side, left side

or rear connection

PS-5238-11-ADR

Flange Mount

• 3/8" or 5/8" Shaft

• Top side, right side, left side

or rear connection

PL-1746-C01

LED Display

Keypad/Display

Power Input

Resolver

I/O Rack
(optional)