Pl-1746 specifications, Continued) – Electro Cam PL-1746 User Manual

Page 7

Advertising
background image

7

Analog outputs accessible through
backplane only; they are proportional
to RPM.

See page 4 for sinking/sourcing definitions.

Plug-In Module

PL-1746-C01-R1

PL-1746-C02-E1-S

PL-1746-C04-R

Part Numbers

PL-1746-C02-R1
PL-1746-C03-E1-S
PL-1746-C03-R1

Outputs On Rack

(cont’)

Output Types

Resolution

Update Frequency

Linearity

Set-up

4-20 mA or 0-10 VDC, proportional to RPM

12 bit

10 ms

±

0.3% of full scale @ 25

°

C (77

°

F)

Offset & full scale RPM are programmable

PL-1746 Specifications

(continued)

Inputs on Module

DC Inputs

Input ON State Voltage

Input Current

Response

8 DC inputs, optically isolated,
sinking

or sourcing

in banks of 4.

20-30 VDC

11 mA @ 24 VDC

2

µ

s max.

Outputs on Module

Real World Outputs

Analog Output

Resolution

Update Frequency

Set-up

6 DC outputs @ 1.5A each, 20-30V

Note: -C02 all outputs are SOURCING

-C03 all outputs are SINKING

12 bit

10 ms

Offset & full scale RPM are
programmable

Operation

Scan Time

Less than 1000

µ

s typical (exact time

determined by programming)

Less than 1000

µ

s typical (exact

time determined by programming).

12 bits (4096 increments)

Position Resolution

12 bits (4096 increments)

12 bits (4096 increments)

Speed Compensation

Programmed in 0.1 msec steps. 16 individually
compensated outputs max. Updated 5 times per
second. Separate leading/trailing edge
compensation standard.

Programmed in 0.1 msec steps. 16
individually compensated outputs max.
Updated 5 times per second. Separate
leading/trailing edge compensation
standard.

Programmed in 0.1 msec steps. 16
individually compensated outputs max.
Separate leading/trailing edge compensa-
tion standard.

1.0 ms time base

(accuracy: +1,-0 ms)

1.0 ms time base

(accuracy: +1,-0 ms)

1.0 ms time base

(accuracy: +1,-0 ms)

Output Timeout

Number of Timed Outputs

Multiple Programs

Total Pulse Memory

Pulses per Program

Pulses per Output

Maximum Speed

Four maximum

48 programs standard

1252 pulses standard

512 maximum standard

512 maximum standard

3000 RPM.

Note: Pulses generated with Pulse

Train command are not included in pulses per
program or pulses per output counts.

Four maximum

48 programs standard

1252 pulses standard

512 maximum standard

512 maximum standard

3000 RPM.

Four maximum

48 programs standard

1252 pulses standard

512 maximum standard

512 maximum standard

3000 RPM.

Note: Pulses generated

with Pulse Train command are not
included in pulses per program or
pulses per output counts.

Less than 1000

µ

s typical (exact time

determined by programming).

Advertising