Plug-in module typical systems, P s - 5 2 x x - x x x - x x x - x, Sinking or sourcing – Electro Cam PL-1746 User Manual

Page 4

Advertising
background image

Component(s)

Qty.

Part Number

PL-1746-C01 System

C01 Plug-In Module

(1)

PL-1746-C01-R1

Resolver

(1)

PS-5275-11-ADR

Resolver Cable

(1)

PS-5300-01-010

Keypad/Display

(1)

PS-6400-24-001

Keypad-to-controller cable(s)

(1)

PS-6300-01-005

I/O Rack

(1)

PS-PS-4108-13-L08

I/O Rack Cable

(1)

PS-4308-10-005

SLIMLINE™ Output Modules

(16)

EC-ODC060-3

SLIMLINE™ Analog Modules

(2)

EC-SANL-010V

PL-1746-C02 System (C03 for

Sinking)

C02/C03 Plug-In Module

(1)

PL-1746-C02-R1

Resolver

(1)

PS-5275-11-ADR

Resolver Cable

(1)

PS-5300-01-010

Keypad/Display

(1)

PS-6400-24-001

Keypad-to-controller cable(s)

(1)

PS-6300-01-005

PL-1746-C04 System

C04 Plug-In Module

(1)

PL-1746-C04-R1

Resolver

(1)

PS-5275-11-ADR

Resolver Cable

(1)

PS-5300-01-010

Keypad/Display

(1)

PS-6400-24-001

Keypad-to-controller cable(s)

(1)

PS-6300-01-005

Plug-In Module

Part Number Breakdown

Resolver

Part Number Breakdown

4

P L - X X X X - XXX - X X - X

SUB-CATEGORY

C01 = Display, 32 Real World I/O with

External I/O racks

C02 = Display, Built-in 8 Inputs and 6

Sourcing

DC Outputs, 1.5 A

C03 = Same as C02, except with

Sinking

outputs

C04 = No Display, No Real World I/O

PL =

Plugs into backplane
Utilizes Allen-Bradley

technology.

OPTIONS

S = Shift Register & Output

assignment feature

NUMBER OF
TRANSDUCERS

1 = One

TYPE TRANSDUCER

R - Resolver
E - Encoder

PLATFORM TYPE

1746 = SLC 500

P S - 5 2 X X - X X X - X X X - X

HOUSING
A
- Can housing w/flange

or foot endbells.

C - Stainless steel

square housing.

E - 74 mm bolt spacing,

flange mount

S - Servo mount

(.12 = size 11;
.38 = size 25 )

LOCATION OF CABLE CONNECTION

W - With stripped & tinned leads
G - Right (120

°

from top on “A” housings)

R - Rear (not available on Geared Resolver)
L - Left (120

°

from top on “A” housings)

S - Side (Top)

TYPE OF CABLE CONNECTION

D - Military bayonet style connector
T - Terminal strip with NO conduit

entrance

V - No connector, just stripped &

tinned wires

S - Sealed connector — screw type

Note:

Part # PS-5903-01-001
conduit entrance for
terminal strip models
sold separately.

OPTION

V - Vertical Mount

Note: Only required
for vertical mounting
of PS-5262-11-CTX
Models.

RATIO

11 - Standard 1:1 (Note: 3rd digit

not used on Standard 1:1)

021 - Geared 2:1 - Ext. shaft to

internal resolver shaft

thru
361
- Geared 36:1 - Ext. shaft to

internal resolver shaft
Various ratios available,
contact Factory.

Resolver

PL

µ

S

Part Number

SHAFT SIZE

12 -

1/8 DIA.

15 -

15 mm DIA.

20 -

20 mm DIA.

38 -

3/8” DIA., 2.06” Bolt Flange

62 -

5/8” DIA., 2.25” Bolt Flange

75 -

3/4” DIA.

Plug-In Module

Typical Systems

SINKING or SOURCING

( as pertaining to Electro Cam Corp. products )

Sinking means that when the logic is true and the output (or
input device) is ON, the output (or input device) is providing a
DC common or ground to the connected device.

Sourcing means that when the logic is true and the output
(or input device) is ON, the output (or input device) is provid-
ing a +DC voltage to the connected device.

This information is important when interfacing an Electro Cam
Corp. product with another electronic device. If you are using
an Electro Cam Corp. product input to an Allen-Bradley 1746-
IN16 “sinking” input card* or similar A-B device, you have to
supply a +DC voltage (Electro Cam Corp.

Sourcing output)

to this card, NOT a DC common or ground. In these cases,
Sinking is what the card does with the input voltage; sinks it
to common or ground.

* Other manufacturers include, but not limited to: Koyo (for-
merly GE Series 1, Texas Instruments, or Siemens SIMATIC
PLS’s) that use descriptions similar to Allen-Bradley.

Advertising