Pl-1746 specifications – Electro Cam PL-1746 User Manual

Page 6

Advertising
background image

Specifications continued...

6

Plug-In Module

PL-1746-C01-R1

PL-1746-C02-E1-S

PL-1746-C04-R1

Part Numbers

PL-1746-C02-R1
PL-1746-C03-E1-S
PL-1746-C03-R1

Electrical

Input Power

Backplane Power

I/O Power

Permanent Memory

Environment

Operating Temp.

Storage Temp.

Humidity

20-30 VDC. Keypad/display is
powered from controller.

5VDC @ 500 mA max.

0

°

to 55

°

C (32

°

to 131

°

F)

-40

°

to 70

°

C (-40

°

to 160

°

F)

95% maximum relative
non-condensing

Keypad/Display: NEMA 4

PL

µ

S Module: 0.5 lbs (0.2 kg)

Keypad/Display: 0.5 lbs. (0.2 kg)

Mounts in SLC-500 chassis.

Brackets accept EN-50035 (“G” profile)
or EN-50022 (“Top Hat” profile) DIN Rail

8 sinking

or sourcing

DC inputs,

optically isolated (1st rack only).

10-30 VDC

11 mA @ 24 VDC

2

µ

s max.

PL-1746 Specifications

See page 4 for sinking/sourcing definitions.

20-30 VDC. Keypad/display is
powered from controller.

5VDC @ 500 mA max.

5 VDC @ 500 mA max.

20-30 VDC, 80 mA + 150 mA
per keypad + 230 mA per rack.

Example: Total = 840 mA with 2 keyboards and 2
racks.

Certain types of power supplies employ a self
protection feature called current fold back
limiting. The inrush currents of the high efficiency
switching regulators may cause power supplies to
enter current limit mode. Power supplies with
current fold back limiting should be sufficient to
supply three times the steady state current of the
system.

Inrush current @ 30v, 40 amps max. for 600

µ

s

(2 keyboards, 2 racks)

20-30 VDC @ 90 mA max. + 150 mA
per PS-6400 keypad

Certain types of power supplies employ a self
protection feature called current fold back
limiting. The inrush currents of the high efficiency
switching regulators may cause power supplies to
enter current limit mode. Power supplies with
current fold back limiting should be sufficient to
supply three times the steady state current of the
system.

EEPROM (no battery required)

EEPROM (no battery required)

EEPROM (no battery required)

NEMA Rating

0

°

to 55

°

C (32

°

to 131

°

F)

-40

°

to 70

°

C (-40

°

to 160

°

F)

95% maximum relative
non-condensing

Keypad/Display: NEMA 4

0

°

to 55

°

C (32

°

to 131

°

F)

-40

°

to 70

°

C (-40

°

to 160

°

F)

95% maximum relative
non-condensing

Keypad/Display: NEMA 4

Physical

Weight

PL

µ

S Module: 0.5 lbs (0.2 kg)

Keypad/Display: 0.5 lbs. (0.2 kg)

PL

µ

S Module: 0.5 lbs (0.2 kg)

Keypad/Display: 0.5 lbs. (0.2 kg)

Mounting

Controller

Rack

Keypad/Display

Mounts up to 1000’ from controller. 0
0 to 2 keypads may be connected to
one controller.

Mounts in SLC-500 chassis.

Mounts up to 1000’ from controller. 0
0 to 2 keypads may be connected to
one controller.

Mounts up to 1000’ from controller. 0
0 to 2 keypads may be connected to
one controller.

Mounts in SLC-500 chassis.

Inputs on Rack

DC Inputs

Input ON State Voltage

Input Current

Response

Outputs on Rack

Real World Outupts

Up to 16 SLIMLINE™ modules may
be mounted on the rack. Modules
may be any mix of AC, DC, and reed
relay. All modules (except reed relay)
optically isolated.

Analog Output

Up to 2 SLIMLINE™ analog output
modules may be mounted on the rack
in addition to the 16 digital modules.

20-30 VDC @ 80 mA max. + 150 mA
per PS-6400 keypad (include power
supply warning).

Advertising