enFORCE

Operation Manual

Code A9_6 - PARAMETER ERROR / DISTANCE SETUP ERROR

One of the Distance presets is out of range

RECOVERY:
1. Verify that the Distance presets are in range for the tool size.
2. Check that the Distance presets are not <0> or setup as specified in 6.4.5.2.

Code A9_7 - PARAMETER ERROR / MANUAL OR RETURN LOAD OVER.

The Manual Load or the Return Load is more than 1/6 of the Full Scale Load.

RECOVERY:
1. Verify there is no excessive binding in the press shaft or press fixture while jogging in manual

mode or while running in the Return portion of the press stroke.

2. If heavy tooling is attached to the press ram causing an excessive load to be seen, set the

“Self Check Off” signal high (on) before sending a “Start” signal.