Mk series, General pump – General Pump MK Owner Manual User Manual

Page 12

Advertising
background image

Page 12

GENERAL PUMP

A member of the Interpump Group

MK SERIES

The filter must be installed as close as possible to the

pump, should allow easy inspection and have the follow-

ing characteristics:

1. Minimum capacity 3 times greater than the pump’s

rated flow value.

2. Filter port diameters must not be smaller than the

pump inlet ports.

3. Filtration degree ranging between 200 and 360 µm.

9.7 Filtering

On the suction line, install two filters as indicated in fig. 7

and fig. 7/a.

With the manual adjustment valve:

With the pneumatic adjustment valve:

In order to guarantee correct pump operation,

it is important to plan periodical cleaning of

the filter depending on actual pump usage,

water quality and real clogging conditions.

9.8 Delivery Line

To obtain a correct delivery line, please comply with the

following installation instructions:

1. The internal diameter of the pump must allow to guar

antee correct fluid speed; see digram in paragraph 9.9

2. The first section of the hose connected to the pump

must be flexible in order to isolate pump vibrations

from the rest of the system.

3. Use high pressure hoses and fittings that guarantee

wide safety margins in any working condition.

4. Install a safety valve on the delivery line.

5. Use pressure switches suitable for the pulsating loads

typical of plunger pumps.

6. In the design phase, take into proper account the

pressure drop along the line, since this causes a

reduction in usage pressure with respect to the value

measured at the pump.

7. If the pump pulsations are harmful for particular appli

cations, install an appropriately sized pulsation damp

ener on the delivery line.

9.9 Internal Diameter of the Hose Line

To determine the internal diameter of the hose, please

refer to the following diagram.

Suction Hose

With a flow rate of ~105 GPM (400 l/mn) and water speed

of 1 m/sec. the diagram line that connects the two scales

intersects the central scale, indicating the diameters, at a

value of ~ 3.5 inch (90 mm).

Delivery Hose

With a flow rate of ~105 GPM (400 l/mn) and water speed

of 5.5 m/sec. The diagram line that connects the two

scales intersects the central scale, indicating the diame-

ters at a value of ~ 1.6 inch (40 mm).

Optimum speed values:

• Suction:

≤ 1 m/sec.

• Delivery:

≤ 5.5 m/sec.

Ref 300669 Rev.B

05-13

Advertising