13. PRECAUTIONS AGAINST FREEZING

In areas and periods of the year where there is

risk of freezing, follow the instructions indicated

in Chapter 12 (see paragraph 12.2).

In the presence of ice, in no case must the

pump be started until the entire circuit has

been completely thawed out; not complying

with this indication may cause serious

damage to the pump.

14. WARRANTY TERMS

The pump is guaranteed for a period of 12 months from

the delivery date or for 1000 hours of operation, with the

exception of parts subject to wear. In any case, please

refer to the contract terms for other warranty conditions.

The warranty is void if:

a) The pump has been used for purposes that differ

from that agreed.

b) The pump has been fit with an electric or diesel

engine with performance greater than that indicated

in the table.

c) The required safety devices were un-adjusted or dis

connected.

d) The pump was used with accessories or spare parts

not supplied by General Pump.

e) Damage was caused by:

1) improper use

2) the non-observance of maintenance instructions

3) use not compliant with operating instructions

4) insufficient flow rate

5) faulty installation

6) incorrect positioning or sizing of the hoses

7) non-authorized design changes

8) cavitation

15. TROUBLESHOOTING

The pump does not produce any noise at

start-up:

• The pump is not primed and is running dry

• There is no water in the inlet line

• The valves are blocked

• The delivery line is closed and does not allow

the air in the pump to be discharged

The pump pulses irregularly (knocking):

• Air suction

• Insufficient feeding

• Bends, elbows, fittings along the suction line

obstruct the fluid’s passage

• The inlet filter is dirty or too small

• The booster pump, where provided, supplies

insufficient pressure or flow rate

• The pump is not primed due to insufficient

head or the delivery line is closed during

priming

• The pump is not primed due to valve seizing

• Worn valves

• Worn pressure packings

• Incorrect operation of the pressure adjust

ment valve

• Transmission problems

The pump does not deliver the rated flow / is

noisy:

• Insufficient feeding (see the causes listed

above)

• RPM are less than the rated flow

• Excessive amount of water by-passed by the

pressure adjustment valve

• Worn valves

• Leakage from the pressure packings

• Cavitation due to:

1) Wrong sizing of the suction hose/

undersized diameters

2) Insufficient flow rate

3) High water temperature

Insufficient pump pressure:

• The nozzle (or has become)too large

• Insufficient RPM

• Leakage from the pressure packings

• Incorrect operation of the pressure adjust-

ment valve

• Worn valves