9.10 V-belt Transmission

As indicated in paragraph 9.1, only in exceptional cases

may the pump be driven by a v-belt system. For correct

lay-out sizing, please contact our Customer Service

Department.

The diagram does not take into account the hose

and valve resistance, the pressure drop due to the

pipe length, the viscosity and the temperature of

the pumped fluid. If necessary, contact our

Customer Service Department.

10. START-UP AND OPERATION

10.1 Preliminary Inspections

Before Start-up Be sure that:

The suction line is connected and up to pres-

sure (see Chapter 9) the pump must never run

dry.

1. The suction line must be perfectly airtight.

2. All the On-Off valves between the pump and

the feeding source are completely open. The

delivery line must discharge freely in order to

allow the air in the pump to be expulsed easi

ly, thus facilitating pump priming.

3. All suction/delivery connections and fittings

must be correctly tightened.

4. Coupling tolerances on the pump/transmis

sion axis (half-joint misalignment, Cardan

inclination, belt tightening, etc.) must remain

within the limits indicated by the transmission

Manufacturer.

5. The pump’s oil level must be verified

using the correct dipsticks (position 1, fig 8).

In case the pump has not run for a long period

of time, recover the correct operation of the

suction valves by opening the three valve-lift-

ing devices (see position 2, fig. 9). Be sure to

reclose the valves before the pump start-up.

See fig. 10 for the valve positions.

Ref 300669 Rev.B

05-13

Advertising