Mk series, General pump – General Pump MK Owner Manual User Manual

Page 9

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

MK SERIES

Page 9

7.INFORMATION ABOUT PUMP USE

The MK pump has been designed to operate

with filtered water (see paragraph 9.7) and at
maximum temperature of 104

0

F (40

0

C).

Other fluids may be used only upon the

approval of The Customer Service

Department

.

7.2 Max Flow Rate and Pressure Values

The performance values indicated in the catalog refer to

the maximum performance of the pump. Regardless of the

power used, pressure and maximum RPM values indicat-

ed on the plate may not be exceeded unless expressly

authorized by the Customer Service Department.

7.3 Lowest RPM

Any RPM value different from what is indicated in the per-

formance table (see chapter 5) must be expressly author-

ized by the Customer Service Department.

7.4 Recommended Lubricant Oil Types & Manufacturers

The pump is delivered with lubricant oil compliant with
room temperatures ranging between 32

0

and 89.6

0

F (0

0

and 30

0

C ). Some recommended lubricant types are indi-

cated in the table below; these lubricants are treated with

additives in order to increase corrosion protection and

resistance to fatigue. As an alternative, Automotive SAE

85W-90 gearing lubricants may also be used.

7.1 WaterTemperature

The max water temperature is 104

0

F (40

0

C).

Nonetheless, it is possible to use the pump at

temperatures of up to 140

0

F (60

0

C) for short

periods of time. In this case we advise con-

sulting the Customer Service Department.

BRAND

TYPE

GENERAL PUMP

SERIES 220

ARAL

Aral Degol BG220

BP

ENERGOL HLP 220

CASTROL

Hyspin VG 220, Magna 220

ELF

POLYTELIS 220

ESSO

NUTO 220

FINA

Cirkan 220

FUCHS

RENOLIN 220

MOBIL

DTE OIL BB

SHELL

TELLUS C 220

TEXACO

RANDO HD 220

TOTAL

CORTIS 220

Check the oil level by using the oil level dipstick (1), fig. 3.

Refill if needed from the oil cap (3), fig 3. Correct oil level

inspection is done with the pump at room temperature; oil

is changed with the pump at working temperature, by

removing the rear plug (2), fig 3..

Checking and changing oil is to be carried out as indicated

in Chapter 11. The amount required is 456.5 oz. (13.5

liters).

In any case, oil must be changed at least

once a year since it may deteriorate by

oxidation.

For room temperatures that differ from that men-

tioned earlier, follow the indications contained in

the diagram below, keeping in mind that the oil

must have a minimum viscosity of 180 cSt.

Exhausted oil must be collected in an appro-

priate recipient and disposed of in appropri-

ate locations. In absolutely no case may it be

dispersed into the environment.

VISCOSITY/ROOM TEMPERATURE DIAGRAM

Ref 300669 Rev.B

05-13

Advertising