Section 7 - Air Supply Installation

Visit our website at: www.lanair.com

19

General Requirements

1. Install an air pressure supply line connection to the air filter/regulator on the rear of the

heater.

2. The air supply source must be capable of producing 2.0 CFM @ 60 PSI.

3. Install a shut off valve in the air supply line for service.

4. Install a primary air filter/regulator with a gauge (capable of reading line pressure) in the

air supply line prior to the air filter/regulator mounted on the furnace. The primary air fil-
ter/regulator is not supplied with the furnace.

5. If the primary air regulator does not have a filter with a bowl, a condensate drain leg

must be installed in the air supply line.

6. Install a quick disconnect at the air filter/regulator on the furnace for service.

7. For the ease of installation install a flexible air line (.250 I.D. minimum) from the quick

disconnect to the primary air regulator.

8. The air supply line must be pitched uphill from the primary regulator to the furnace to

prevent condensation from entering your burner.

9. Open all air shut off valves, and set the primary air regulator at 30 PSI.

10. Set the air filter/regulator on the front of the furnace to 15 LBS. See illustration below

(Fig. 5) for a typical air pressure supply installation.

Figure 5

Section 13 - Service / Maintenance

QUESTIONS?... Contact Customer Service at 1-800-753-1601 M-F 8:00 am- 4:15 pm CST

34

Maintenance - Air Pre-Heater

1.

Remove Pre-Heater Assembly

• Disconnect the air line from the

brass fitting on the air pre-heater
and then from

the air solenoid and remove.

• Disconnect wiring from the oil pre-

heater cartridge, air pre-heater
cartridge and snap disc assembly in
the wiring junction box.

• Disconnect fuel line and fitting (6)

from the oil block (5).

• Disconnect fuel pressure gauge (8)

and fitting from the oil block (5).

• Remove button hex screw (14) and

washer (11).

• Lift pre-heater assembly and care

fully pull straight back. Remove
entire assembly from the burner.

• Remove ignitor assembly (6).

2. Remove Diaphragm Assembly

from Air Pre-Heater
• Carefully place pre-heater assembly

in a vice. NOTE: Do not damage
pre-heater.

• Unscrew diaphragm assembly (19)

from air pre-heater and set aside.
Remove o-ring and discard.

3. Remove Adapter Assembly

• Remove hex cap screws (17) and set adapter

assembly aside.

4. Remove Plunger , Spring and Cartridge Heater

• Remove spring (13) from plunger (15) and discard.
• Using a hook or screwdriver, carefully remove Viton

insert (14) and discard.

• Remove and discard 1/4" o-ring (10) and 11/16" o-

ring (11).

• Loosen and remove cartridge heater and set aside.

5. Remove Nozzle Assembly and Quad Ring

• Remove nozzle assembly (3) using a 9/16" wrench.
• If quad ring (4) does not come out with nozzle, care

fully remove it and discard.

Ref.

Part

No.

No.

Qty.

Description

1

9853

1

turbulator

2

7004

1

set screw

3

9757

1

nozzle Heater 260/300

4

9870

1

quad ring (K)

5

9814

1

air pre-heater block

6

3730

1

ignitor assembly

7

9870

2

hex cap screw *

8

7418

2

flat washer

9

3726

1

connector

10

9870

1

1/4" o-ring *

11

9870

1

11/16" o-ring *

12

9856

1

air cartridge heater

13

9870

1

spring *

14

9870

1

Viton insert *

15

9835

1

plunger

16

9838

1

Adapter block assembly

17

9870

2

hex head cap screw *

18

9871

1

1/2" o-ring (K)

19

9871

1

diaphragm assembly **

20

9871

2

hex head cap screw **

22

oil pre-heater block

* contained in tune up kit 9870

** contained in tune-up kit 9871

Remove wires from the block by
inserting a flat tip screwdriver into the
top slot. Push tip all the way down
and carefully push forward. Remove
wire.

Advertising