Lanair DHI 300 User Manual

Page 5

Advertising
background image

Section 1 - General Specifications & Hazards

Visit our website at: www.lanair.com

5

1

3

2

2

2

4

8

5

6

7

9

No.

Description

1

8" Chimney Exhaust

2

Mounting Holes

3

Fan Hi-Limit Switch

4

Flame View Port

5

Burner Assembly

6

Electrical Power Box

7

Electrical Panel Access

8

Clean-Out Port Access Panel

9

Blower Assembly

Section 14 - Troubleshooting

QUESTIONS?... Contact Customer Service at 1-800-753-1601 M-F 8:00 am- 4:15 pm CST

48

Symptom

Possible Cause

Corrective Action

C. Burner fires, and then

1. Contaminated fuel supply

1. Drain and clean fuel

fails on oil primary safety

(water/anti freeze/gear lube)

supply tank. Clean fuel

or dirty fuel filter.

filter (see page 37)

2. Improper draft

2. Check draft see page 15.

Make sure chimney is
properly installed

3. Plugged heat exchanger,

3. Clean heater including

manifold, or chimney

manifold and chimney

4. Wrong air pressure

4. See flame adjustment pages

29-31

5. Wrong fuel pressure or

5. See flame adjustment

pressure fluctuating

pages 29-31. See fuel piping
page 17

6. Improper combustion blower

6. See flame adjustment

setting, or blower is defective

pages 29-31. See fuel piping
page 17

7. Oil primary/cad cell defective.

7. Test components/adjust

Cad cell improperly adjusted.

cad cell/ clean turbulator

Dirty flame turbulator.

8. Plugged nozzle or pre-heater

8. Clean nozzle and /or

assembly

pre-heater assembly

D. Pre-heater assembly

1. Cartridge heaters defective

1. Test cartridge heaters

not heating

or disconnected

using an ohm meter.
Air heater 112

Ω ±10%.

Oil heater 37

Ω ±10%.

2. Snap disc defective

2. Test snap switch for

continuity if
pre-heater is cold

3. Hi-Limit snap disc defective

3. Replace snap disc assembly

Advertising