Calibrate – LOCKSTATE LS-60 Operation Guide User Manual

Page 12

Advertising
background image

PG

12

PG

12

CALIBRATE

Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient

temperature. You do have the option, however, to change the display temperature to match that of a

previous thermostat, or to match another thermostat already in your home. The range of change is

from -6°F to +6°F or -3°C to +3°C.

To change your Thermostat Calibration,
touch MENU and then touch CALIBRATE.

Use the + / - to adjust the displayed temperature up or down, as desired.

The DELTA FACTOR that appears on the screen will also automatically increase or decrease

for each 0.5° (F or C) adjustment so you can see your change. The large display will show the

modified temerature reading that will be displayed on the HOME screen and used as the new room
temperature.

Touch

to return to the Home screen.

DIFF

(Used for 2 stage normal or heat pump with auxiliary only, not on screen for single stage)

The differential is the number of degrees between the room temperature and the Target Temperature

at which the 2nd stage will be used. Default is 2°F.

Touch MENU and then DIFF. Use the arrows to set the DIFF.

Recommend 2°F for very cold climates and the 4°F for warm climates.