Annual service, Cleaning outer surfaces, Servicing – Aarrow Fires Gas Stove User Manual

Page 27

Advertising
background image

ANNUAL SERVICE

THIS GAS APPLIANCE MUST BE SERVICED
EVERY TWELVE MONTHS BY A QUALIFIED
GAS ENGINEER.

See "SAFETY NOTICES" ref coal set page 3.

Ensure the appliance is cold.

Step 1 Isolate the gas supply from the stove.
Step 2 Remove the outer body of the stove.
Step 3 Remove the glass.

Important: If the glass is broken or cracked or
the glass gasket is damaged they must be
replaced before the stove is used.

Step 4 Carefully remove and clean the loose coal

/ logs set of any soot deposits using a soft
brush.

Step 5 Clean the firebox of any soot deposits

using a soft brush.

Step 6 Carefully lift out and clean the base coal

matrix. Important: If any of the ceramic
components are damaged they must be
replaced with original Aarrow parts.

Step 7 Clean the burner top and surrounding

areas with a vacuum cleaner.(See safety

notices on page 3).

Step 8 Inspect the pilot assembly to ensure that it

is clean, unobstructed and in good work
ing order.

Step 9 Looking into the flue from inside the

stove check that it is clear of any debris or
obstructions.

Step 10 Check the system for gas soundness.
Step 11 Check the ignition of the pilot and with

the pilot turned off check that the flame
failure system is working.

Step 12 Relocate the base coal matrix (4x piece).
Step 13 Relocate and position the loose coals or

re-assembly the log set.

Step 14 Light the pilot and check the operation of

the stove and the flame picture.

Step 15 Relocate the glass frame assembly,

ensuring all the screws are replaced and
secure. (Use original screws only.)

Step 16 Refit the dummy fuel retainer.(2x screws)
Step 17 Relocate the outer body of the stove.
Step 18 If the stove is rear flued proceed to fit the

top flue cover plate into the canopy
cutout ensuring the front tab is located
under the canopy (see page 25, step 1a).
Place the valve cover in front of the

control valve.

Step 19 If the stove is top flued, proceed to fit the

top flue infill piece (see page 25, step
1b). Place the valve cover in front of the
control valve.

CLEANING OUTER SURFACES

It is best cleaned using a soft brush. Do not allow
moisture to remain on the top while cold or
surface rust may occur.

Aarrow Sherborne GSL CF

27

SERVICING

Advertising