Servicing – Aarrow Fires Gas Stove User Manual

Page 28

Advertising
background image

28

Aarrow Sherborne GSL CF

SERVICING

Is the gas supply
turned on?

Does the pilot

ignite?

Yes

Does the pilot
stay alight?

Yes

Does the main
burner light?

Yes

No

Is their air in
the system?

Yes

Is the main
injector blocked?

Yes

Clean and
replace as
necessary

Is the supply
pressure
correct?

No

Is the
thermocouple
o.k.?

No

Check gas supply and operation of
control valve. Replace if necessary.

Is their a spark at the
electrode?

No

Is pilot flame the correct
size & playing onto
thermocouple

Replace the pilot
OSD assembly

No

No

No

Turn gas
on

Purge system

Yes

Correct
pressure

No

Replace pilot

assembly

OSD

No

Yes

Check for
spark output
from control
valve.

Yes

Check if gas
is passing
from control
valve.

Yes

No

Replace pilot
OSD assembly

Yes

No

Confirm supply
pressure is correct

FAULT DIAGNOSIS

START

Does the stove
stay alight?

Yes

Fire satisfactory

No

Investigate for blocked chimney
and adaquate ventilation check
spillage. If their is no obvious
blockage, seek expert advise.

No

Replace
control
valve

Yes

Replace pilot
OSD assembly

Investigate control valve
operation and replace if necessary.

OSD
PILOT -
Oxygen
Sensing
Device
Pilot

Advertising