THERMOSTAT AND TIMER REMOTE CONTROL

TRANSMITTER FUNCTIONS

Set the display (from *C/24 h to *F/12 h and vice versa)
• After connecting the battery or by simultaneously pressing AUTO and TIMER, the display flashes you
are in set mode.

• From set mode, press AUTO to switch from *F (and 12 hour clock) to *C (and 24 hour clock)

• The display will automatically return to manual mode after some time, but you may immediately return
ual by depressing the TIMER button.

Set the current time

• After connecting the battery or by simultaneously pressing AUTO and TIMER, the display flashes you

are in set mode.

• From set mode, press ( A ) to set the hour and ( B ) to set the minute.

• Wait or press TIMER to return to “manual” mode.

Programming the Desired Set Temperature

• Press AUTO until the display flashes

• Press ( A ) or ( B ) to the desired temperature.

• Wait or press AUTO to switch to automatic mode.

• A sensor in the remote control measures the room temperature. The controller compares the room temper-

ature with the set temperature and sends a signal to the receiver to turn the gas valve motor, which adjusts

the flame height accordingly.

Programming the Timer

• Press TIMER until P1* (start) flashes (period 1. heating cycle on).

• Set the time for the beginning of the first heating period by pressing ( A ) for hour and ( B ) for minute.

• Press TIMER again P1* disappears and the symbol P1) (finish) appears.

• Set the time for the end of the first heating period.

• Press TIMER again to set the second heating period P2* (start) and P2) (finish).

• Store both heating periods by pressing TIMER again.

NOTE! If only one heating period is desired, programme the same time for P2* and P2) as for P1* and